CABLE BURNING TEST DEVICE

CABLE BURNING TEST DEVICE DVT YAN K2 DVT YAN K2

It is used to determine burning protection limits of cables and solid electrical insulation materials and their inflammability when exposed to a specific amount of flame.

INDUSTRIAL SECTORS OF USE

TECHNICAL INFORMATION

  • Air and propane inlet
  • Digital screen
  • #2 time displays (burning/extinction time)
  • #1 temperature display
  • Operating voltage: 220VAC, 50 Hz.
  • Power: 300 watt
  • Test cabin dimensions (approximate)(W*D*H): 240*450*780 mm
  • Gas burner angle options: 25-45-90°
  • Temperature probe maximum 750°C
  • Temperature display resolution 0,1°C
  • PT100 PRT sensor sensitivity 0,1°C
  • PID electronic control system
  • Stainless steel cabin/Electrostatic powder coated control panel
  • Allowable ambient temperature (+20°C) to (+30°C)
  • Allowable ambient relative humidity maximum 70%
  • Cabin aeration; fan air extraction
  • Time display minute : second
  • Flame duration setting 0-99 s
  • Extinction waiting period 0-99 s
  • Beep upon expiration of period
  • Premixed gas burner
  • Needle air and gas adjustment
  • Air flow rate pressure adjustment
  • Air and propane on/off valve
  • Cabin smoke extraction fan
  • Tempered glass door

INDUSTRIES OF APPLICATION

  • Cable manufacturing

TESTS PERFORMED WITH THE DEVICE

  • Tests mentioned in the standard EN 60332-1-2.

PRODUCTS SUBJECT TO TESTING

  • Cables
  • Cable insulations
  • Cable sheaths

OPTIONAL ADDITIONS

  • Automatic igniter system
  • DLC touch-screen
  • Continuous thermometer
  • Pneumatic gas burner movement

APPROXIMATE DIMENSIONS AND WEIGHT

  • Width: 550 mm
  • Depth: 485 mm
  • Height: 1341 mm
  • Weight: 45 kg

TECHNICAL DOCUMENTATION

Specification Sheet

RELEVANT STANDARDS

  • TS EN 60695-11-2
  • EN 60695-11-2